Light is flickering or the brightness varies unpredictably.

  1. Evaluate if any potential EMI producing equipment is in the vicinity (high voltage welding equipment, etc.).
  2. Do not route output power to the light in the same wire-chase as the trigger lines if possible. High current pulses can cause noise to couple into the trigger.
  3. Use shielded trigger cables.

When strobing, the images are dark or inconsistent in brightness.

  1. Reduce the trigger frequency, shorten the pulsewidth, or reduce the current until the maximum frequency is no longer exceeded.

I can’t get the trigger to work

  1. Follow the recommended trigger wiring diagrams in the manual. Try checking or un-checking the “differential triggers” option in the S320 software.  Contact our Customer Service for assistance.

The software doesn’t allow me to adjust any settings (all grayed–out).

  1. Verify the light is connected and that the components inside the “C5” connector are all tightened down completely.
  2. Avoid extending the cable yourself. If you’ve added an extension cable it must be under 2m long, else contact the factory for assistance.
  3. If you’re not using an AI branded “C5” light, the output needs a SignaTech identifier, so it will not work unless one was provided to you from the factory.

I am getting an error-code which is not listed in the manual.

  1. Contact our Customer Service for assistance.